Search results for " Actuator"

showing 10 items of 50 documents

Decoupled nonlinear adaptive control of position and stiffness for pneumatic soft robots

2020

This article addresses the problem of simultaneous and robust closed-loop control of joint stiffness and position, for a class of antagonistically actuated pneumatic soft robots with rigid links and compliant joints. By introducing a first-order dynamic equation for the stiffness variable and using the additional control degree of freedom, embedded in the null space of the pneumatic actuator matrix, an innovative control approach is introduced comprising an adaptive compensator and a dynamic decoupler. The proposed solution builds upon existing adaptive control theory and provides a technique for closing the loop on joint stiffness in pneumatic variable stiffness actuators. Under a very mi…

0209 industrial biotechnologyAdaptive controlComputer science02 engineering and technologynull-spaceSoft robotadaptive controlComputer Science::Robotics020901 industrial engineering & automationArtificial IntelligenceControl theoryPosition (vector)0202 electrical engineering electronic engineering information engineeringmedicineElectrical and Electronic Engineeringvariable stiffness actuatorsPneumatic actuatorApplied MathematicsMechanical EngineeringStiffnessNonlinear adaptive controlphysical human–robot interactionantagonistic driveModeling and SimulationJoint stiffnesspneumatic actuatorRobot020201 artificial intelligence & image processingmedicine.symptomSoftware
researchProduct

Comparison of Model-Based Simultaneous Position and Stiffness Control Techniques for Pneumatic Soft Robots

2020

Soft robots have been extensively studied for their ability to provide both good performance and safe human-robot interaction. In this paper, we present and compare the performance of two model-based control techniques with the common aim to independently and simultaneously control position and stiffness of a pneumatic soft robot’s joint. The dynamic system of a robot arm with flexible joints actuated by a pneumatic antagonistic pair of actuators, so-called McKibben artificial muscles, will be regarded, while its dynamic parameters will be considered imprecise. Simulation results are provided to verify the performance of the algorithms.

0209 industrial biotechnologyAdaptive controlPneumatic actuatorComputer scienceAdaptive controlModel based controlStiffnessAntagonistic drive02 engineering and technologySoft robotsVariable stiffness actuator020901 industrial engineering & automationSettore ING-INF/04 - AutomaticaPosition (vector)Control theoryPneumatic actuator0202 electrical engineering electronic engineering information engineeringmedicineRobot020201 artificial intelligence & image processingArtificial musclemedicine.symptomActuatorRobotic arm
researchProduct

Guidelines to Select Between Self-Contained Electro-Hydraulic and Electro-Mechanical Cylinder

2020

This research paper presents guidelines on how to select between self-contained electro-hydraulic and electromechanical cylinders. An example based on the motion control of a single-boom crane is studied. The sizing process of the different off-the-shelf components is analyzed in terms of design impact when replacing a traditional valve-controlled hydraulic cylinder. The self-contained electro-hydraulic solution is the best choice when a risk for high impact forces is present, when the required output power level lies continuously above 2 kW, or when installation space, weight, and cost are critical design objectives. However, the electro-mechanical solution is expected to show more control…

0209 industrial biotechnologyComputer scienceStiffnessComputingMilieux_LEGALASPECTSOFCOMPUTING02 engineering and technologyLinear actuatorMotion controlSizingCylinder (engine)law.inventionControllabilityHydraulic cylinder020901 industrial engineering & automation020401 chemical engineeringlawControl theoryLinear motionVDP::Teknologi: 500::Maskinfag: 570medicine0204 chemical engineeringmedicine.symptomHydraulic machineryActuator
researchProduct

A Comparison Study of a Novel Self-Contained Electro-Hydraulic Cylinder versus a Conventional Valve-Controlled Actuator—Part 2: Energy Efficiency

2019

This research paper presents the second part of a comparative analysis of a novel self-contained electro-hydraulic cylinder with passive load-holding capability against a state of the art, valve-controlled hydraulic system that is typically used in load-carrying applications. After addressing the control design and motion performance in the first part of the study, the comparison is now focused on the systems&rsquo

0209 industrial biotechnologyControl and OptimizationComputer scienceHydraulicspassive load-holdingenergy recoveryComputerApplications_COMPUTERSINOTHERSYSTEMS02 engineering and technologyAutomotive engineeringlaw.invention020901 industrial engineering & automationlinear actuatorslawload-carrying applications0202 electrical engineering electronic engineering information engineeringHydraulic machineryenergy efficiencyEnergy recoveryVDP::Teknologi: 500::Materialteknologi: 520020208 electrical & electronic engineeringEnergy consumptionLinear actuatorFluid powerControl and Systems Engineeringproportional directional control valvesActuatorself-contained cylinderselectro-hydraulic systemsEfficient energy useActuators
researchProduct

A Novel Solution for the Elimination of Mode Switching in Pump-Controlled Single-Rod Cylinders

2020

This paper concerns the stability issue of pump-controlled single-rod cylinders, known as mode switching. First, a review of the topic is provided. Thereafter, the most recently proposed solution for the elimination of mode switching is investigated and shown to result in unstable behavior under certain operating conditions. A theoretical analysis is provided demonstrating the underlying mechanisms of this behavior. Based on the analysis, a novel control strategy is proposed and investigated numerically. Proper operation and stability are demonstrated for a wide range of operating conditions, including situations under which the most recently proposed solution results in unstable behavior a…

0209 industrial biotechnologyControl and OptimizationMaterials science020209 energy02 engineering and technologyelectrohydraulic valvesStability (probability)020901 industrial engineering & automationlinear actuatorsControl theorylcsh:TK1001-18410202 electrical engineering electronic engineering information engineeringlcsh:TA401-492large inertia loadsLinear actuatorstabilitylcsh:Production of electric energy or power. Powerplants. Central stationsRange (mathematics)VDP::Teknologi: 500single-pump circuitsmode switching instabilityControl and Systems EngineeringoscillationsMode switchinglcsh:Materials of engineering and construction. Mechanics of materialsActuatorpump-controlled systemsActuators
researchProduct

A Comparison Study of a Novel Self-Contained Electro-Hydraulic Cylinder versus a Conventional Valve-Controlled Actuator—Part 1: Motion Control

2019

This research paper presents the first part of a comparative analysis of a novel self-contained electro-hydraulic cylinder with passive load-holding capability against a state of the art, valve-controlled actuation system that is typically used in load-carrying applications. The study is carried out on a single-boom crane with focus on the control design and motion performance analysis. First, a model-based design approach is carried out to derive the control parameters for both actuation systems using experimentally validated models. The linear analysis shows that the new drive system has higher gain margin, allowing a considerably more aggressive closed-loop position controller. Several b…

0209 industrial biotechnologyControl and OptimizationSettling timeComputer sciencepassive load-holding020209 energy02 engineering and technologyactive damping020901 industrial engineering & automationlinear actuatorsmodeling and simulationControl theoryPosition (vector)load-carrying applications0202 electrical engineering electronic engineering information engineeringOvershoot (signal)feedback control systemsLinear actuatorMotion controlControl and Systems EngineeringRise timeproportional directional control valvesActuatorself-contained cylinderselectro-hydraulic systemslinear control designActuators
researchProduct

Computational Analysis of the Active Control of Incompressible Airfoil Flutter Vibration Using a Piezoelectric V-Stack Actuator

2021

The flutter phenomenon is a potentially destructive aeroelastic vibration studied for the design of aircraft structures as it limits the flight envelope of the aircraft. The aim of this work is to propose a heuristic design of a piezoelectric actuator-based controller for flutter vibration suppression in order to extend the allowable speed range of the structure. Based on the numerical model of a three degrees of freedom (3DOF) airfoil and taking into account the FEM model of a V-stack piezoelectric actuator, a filtered PID controller is tuned using the population decline swarm optimizer PDSO algorithm, and gain scheduling (GS) of the controller parameters is used to make the control adapti…

Airfoil020301 aerospace & aeronautics0209 industrial biotechnologyactive flutter suppressionV-stack actuatorComputer sciencePID controller02 engineering and technologylcsh:QC1-999Vibrationpopulation decline swarmoptimizer020901 industrial engineering & automationGain scheduling0203 mechanical engineeringFlight envelopeControl theoryFluttergain schedulingpopulation decline swarm optimizerSettore ING-IND/04 - Costruzioni E Strutture AerospazialiActuatorlcsh:PhysicsVibration
researchProduct

An Intelligent System for Energy Efficiency in a Complex of Buildings

2012

Energy efficiency has nowadays become one of the most challenging task for both academic and commercial organizations, and this has boosted research on novel fields, such as Ambient Intelligence. In this paper we address the issue of timely and ubiquitous monitoring of building complexes in order to optimize their energy consumption, and present an intelligent system addressed to the typical end user, i.e. the administrator, or responsible operator, of the complex. A three-level architecture has been designed for detecting the presence of the building inhabitants user and understanding their preferences with respect to the environmental conditions in order to optimize the overall energy eff…

Ambient Intelligence Energy Efficiency Wireless sensor and actuator networks
researchProduct

A Self-Contained Electro-Hydraulic Cylinder: Modeling, Control Design, Simulation and Experimental Validation

2018

Master's thesis Mechatronics MAS500 - University of Agder 2018 In the constant effort to improve the efficiency of hydraulic systems, the pressure drop over hydraulic valves has been one of the major obstacles. In the Self-Contained Electro-Hydraulic Cylinder, the directional valve and the hydraulic power unit have been replaced by a bi-directional axial piston pump and a Permanent Magnet Synchronous Motor. Actuation of the cylinder is performed by controlling the direction of rotation and the velocity of the motor. Originally the purpose of this project was to: "Design a proper control algorithm for an existing novel selfcontained electro-hydraulic cylinder, implement it on the main boom o…

Axial Piston PumpVDP::Teknologi: 500::Informasjons- og kommunikasjonsteknologi: 550::Teknisk kybernetikk: 553Control DesignFluid PowerVDP::Teknologi: 500::Maskinfag: 570MAS500Asymmetric ActuatorPermanent Magnet Synchronous MachineExperimentsElectric DrivesModellingSelf-Contained Electro Hydraulic CylinderPassive Load Holding
researchProduct

Study of the performances of a fluidynamic actuator

2018

Aim of this paper is presented a new methodology to study how different geometric parameters affect the performance of a hydraulic actuator. Preliminarily, the real working conditions of a hydraulic machine have been simulated by means of a CFD module. After, to test the reliability of the simulations, the obtained numerical results have been compared with the experimental data of a real prototype. This comparison demonstrates a good level of agreement between numerical and experimental results. Different simulations have been setup by modifying the actuator geometry and evaluating the efficiency of every analysed configuration. The results of this study give useful guidelines for the choic…

CFD CAD model hydraulic actuator experimental analysis numerical simulation
researchProduct